🇬🇧 ENGLISH

Titanium Stub End

Titanium Stub End supplied by titanium grade, outside diameter or NPS, wall thickness, end preparation, dimensional standard and inspection requirements for corrosion-resistant piping systems.

Material
Titanium Grade 2, Grade 7 or Grade 12 as specified
Product Standard
ASTM B363 / ASME SB363 where applicable
Dimensions
ASME B16.9, B16.11 or approved drawing
Documents
MTC, dimensions and heat/lot traceability
CONTACT US

Product Detail

Product Introduction

Titanium stub ends form the process-wetted lap used with a rotatable backing flange. This family page covers the selection boundary: identify Type A, Type B or Type C where applicable, long or short pattern, titanium grade, NPS or OD, wall, lap outside diameter and thickness, face, radius, overall length, welding end and matching lap-joint flange.

How should a titanium stub end be matched to a lap joint flange?

Selection answer: A stub end provides the wetted lap and weld end used with a rotating backing flange. Select short or long pattern, lap geometry, outside diameter, wall or schedule and grade to match the connected pipe and flange assembly.

Selection boundary: The stub end and backing flange have separate material and dimensional functions. Their lap radius, thickness, facing contact, pipe bore, weld end and pressure design must be reviewed together.

RFQ data to confirm: Provide stub-end pattern, grade, NPS or OD, wall or schedule, overall length, lap diameter and thickness, corner radius, weld end, backing-flange details, service conditions, quantity, inspection and certificates.

Product Specifications

ProductTitanium Stub EndMaterial OptionsTitanium Grade 2, Grade 7 or Grade 12 as specified
FormsLap-joint stub end, Type A, B or C as specifiedTypical Inquiry RangeNPS 1/2 to 24 typical inquiry range; lap and length by standard or drawing
Product StandardASTM B363 / ASME SB363 where applicableDimensional BasisASME B16.9, ASME B16.11 or approved drawing as applicable
WallSchedule or nominal wall thickness matched to the connected pipe and designEndsButt-weld end with specified lap face
ManufacturingSeamless, welded, formed, forged, machined or fabricated as specifiedSurfacePickled, cleaned, machined or project-specific finish
InspectionVisual, dimensions, wall, ends and specified NDTDocumentsMTC, heat/lot traceability and inspection report

Typical ranges are quotation guidance, not a stock guarantee. Final availability and tolerances are confirmed against the complete RFQ and design code.

Selection and Configuration

  • Complete lap-joint assembly: Review stub end, backing flange, gasket and bolting as one joint; the backing flange is not the wetted sealing lap.
  • Stub-end form: State Type A, B or C when the invoked standard uses that designation, plus long or short pattern and manufacturing route.
  • Mating dimensions: Coordinate pipe OD and wall, lap OD and thickness, corner radius, face finish, bore, weld end and backing-flange clearance.
Pressure-design note: Dimensional conformity does not by itself establish pressure rating. The piping designer must verify material allowable stress, wall thickness, weld joint, corrosion allowance, temperature and governing construction code.

Send the piping specification or drawing
Include grade, NPS or OD, wall/schedule, geometry, ends, quantity, tests and documents.

Request a Quotation

Chemical Composition

Weight percent; maximum unless a range is shown. Titanium is the balance. The ordered grade controls.

Grade / UNSPdMo / NiFeOCNHTi
Grade 2 / R504000.300.250.080.030.015Balance
Grade 7 / R524000.12–0.25 Pd0.300.250.080.030.015Balance
Grade 12 / R534000.20–0.40 Mo; 0.60–0.90 Ni0.300.250.080.030.015Balance

Mechanical Properties – Annealed Source Material Reference

GradeUltimate Tensile Strength min0.2% Yield Strength minElongation min
Grade 2345 MPa (50 ksi)275 MPa (40 ksi)20%
Grade 7345 MPa (50 ksi)275 MPa (40 ksi)20%
Grade 12483 MPa (70 ksi)345 MPa (50 ksi)18%

Representative wrought-source material minima. Fitting acceptance, heat treatment and test specimens must follow the ordered material/product specification and size.

Typical Physical Properties

GradeDensityElastic ModulusThermal ConductivityThermal Expansion
Grade 24.51 g/cm³Approx. 105 GPaApprox. 16.4 W/m·KApprox. 8.6 µm/m·K
Grade 7Approx. 4.51 g/cm³Approx. 105 GPaApprox. 16 W/m·KApprox. 8.6 µm/m·K
Grade 12Approx. 4.54 g/cm³Approx. 103 GPaApprox. 16 W/m·KApprox. 8.6 µm/m·K

Typical engineering references, not inspection acceptance limits.

Certificates & Inspection Records

SAKY ALLOY quality management system certificate

Services We Can Provide

Specification ReviewGrade, dimensions, wall, ends and code requirements.
Custom FabricationLarge, non-standard and drawing-specific geometry by review.
End PreparationBevel, socket, thread, machined or project-defined ends.
NDT CoordinationPT, RT and other agreed examinations with reports.
TraceabilityMTC, heat/lot records and dimensional inspection.
Export SupportProtected packing, labels and shipping documents.

Product Packaging

Fittings are capped or wrapped to protect clean ends, bevels, threads and machined faces. Items are separated by grade, size and heat/lot, then packed in reinforced cartons or export cases according to geometry and quantity.

Application Scenarios

Chemical processing plant with industrial process piping

Chemical Processing

Corrosion-resistant piping for acids, chlorides and process media after grade compatibility review.

Wind turbines and solar panels at a renewable energy site

Power & Energy

Cooling-water, condenser and auxiliary piping requiring traceable titanium components.

Cargo vessel moored for marine service

Marine & Desalination

Seawater and chloride-bearing piping systems designed for the selected titanium grade.

FAQ

Is a stub end used without a backing flange?

A lap-joint stub end normally provides the wetted lap while a compatible backing flange supplies the bolting load. The complete joint must be specified together.

Which dimensions are critical?

State pipe size and wall, lap OD and thickness, face and radius, length, bore, weld end and backing-flange clearance.

Does ASTM B363 alone define every stub end?

No. Invoke the material and fitting requirements plus the dimensional standard, type, pattern and all project-specific inspection and documentation.

Leave Your Message

Related Technical Guides

WhatsApp