ASTM F136 Grade 23 Titanium Sheet and Plate

Extra-low-interstitial Ti-6Al-4V sheet and plate for surgical implant manufacturing, supplied with order-defined dimensions, condition, melt route, microstructure, testing and documentation.

Material
Ti-6Al-4V ELI / Grade 23 / UNS R56401
Standard
ASTM F136 (current purchase-order edition)
Form
Sheet, plate or cut blank as specified
Documents
MTC, heat/lot traceability and agreed inspection reports
CONTACT US

Product Detail

Product Introduction

ASTM F136 Grade 23 Titanium Sheet and Plate is ordered for a specific engineering and procurement route rather than selected from grade name alone. The RFQ must identify the governing standard and revision, grade, product dimensions, condition, surface, tests and documentation needed by the finished component manufacturer.

Product Specifications

ProductASTM F136 Grade 23 Titanium Sheet and PlateGradeTi-6Al-4V ELI / Grade 23 / UNS R56401
StandardASTM F136 (current purchase-order edition) applies only when expressly invoked and when its scope covers the ordered product form and grade. Use the purchase-order revision and do not substitute ASTM B265, ASTM F67, ASTM F136 or AMS4911 without written technical approval.Size & FormSheet, plate and cut-to-size blanks by exact thickness, width, length or drawing dimensions
ToleranceApplicable product standard and order-defined thickness, width, length, flatness, edge, surface and cut-blank tolerancesSupply ConditionHot rolled or cold rolled, annealed, descaled, pickled, ground, polished, waterjet cut, saw cut or machined as agreed
InspectionReview of material certificate and heat identity, chemistry and mechanical tests, thickness/width/length, flatness and surface, edge or cut-blank dimensions, plus ultrasonic, microstructure or supplementary reports when ordered.DocumentsMTC, heat/lot traceability and agreed inspection reports

Send the complete material RFQ
Include grade, specification revision, dimensions, tolerance, quantity, condition, tests and destination.

Request a Quotation

Chemical Composition

Weight percent; maximum unless a range is shown. Titanium is the balance. The ordered specification and grade control.

Grade / UNSPrincipal Alloying ElementsFe maxO maxC maxN maxH maxTi
Grade 23 / R56407Al 5.50–6.50; V 3.50–4.500.250.130.080.050.0125Balance

Mechanical Properties – Annealed Material Reference

GradeUltimate Tensile Strength min0.2% Yield Strength minElongation min
Grade 23860 MPa795 MPa10%

Representative minima only. Product form, section size, heat treatment and the invoked specification determine the certified acceptance values.

Typical Physical Properties

GradeDensityElastic ModulusThermal Expansion
Grade 234.43 g/cm³Approx. 114 GPaApprox. 8.6 µm/m·K

Typical engineering references, not inspection acceptance limits.

Certificates & Inspection Records

SAKY ALLOY quality management system certificate

Services We Can Provide

Specification ReviewGrade, revision, condition and supplementary requirements.
Cut-to-Size SupplyDimensions, machining allowance and tolerances by review.
InspectionDimensions, surface, chemistry and mechanical documentation.
Testing OptionsPMI, UT, PT or other agreed testing where applicable.
TraceabilityMTC, heat/lot identity and inspection records.
Export SupportProtected packing, labels and shipping documents.

Product Packaging

Sheet and plate surfaces are interleaved or wrapped as required, protected at edges and secured on pallets or in export cases with grade, heat and dimensional identification. Typical export packaging for the same physical product form is shown below; final packing is confirmed for each order.

Typical export packaging for this product form

Application Scenarios

Orthopedic and surgical implant components application environment

Orthopedic and surgical implant components

Material grade, dimensions, condition and inspection must be matched to the application requirements.

Medical-device plates and machined blanks application environment

Medical-device plates and machined blanks

Material grade, dimensions, condition and inspection must be matched to the application requirements.

High-strength biocompatible component stock application environment

High-strength biocompatible component stock

Material grade, dimensions, condition and inspection must be matched to the application requirements.

FAQ

Can another titanium plate standard be substituted?

Only with written technical approval. Standards can differ in scope, grade designation, condition, testing, microstructure, melt route and documentation.

Which dimensions should be included in the RFQ?

Provide thickness, width and length or a controlled drawing, tolerances, flatness, edge/cut condition and machining allowance.

What documentation can be requested?

State the required MTC, heat/lot traceability, chemistry, tensile results, dimensional report, ultrasonic or microstructure report and regulatory or aerospace documents.

Leave Your Message

Related Technical Guides