Welded Titanium Fittings
Welded Titanium Fittings supplied by titanium grade, outside diameter or NPS, wall thickness, end preparation, dimensional standard and inspection requirements for corrosion-resistant piping systems.
- Material
- Titanium Grade 2, Grade 7 or Grade 12 as specified
- Product Standard
- ASTM B363 / ASME SB363 where applicable
- Dimensions
- ASME B16.9, B16.11 or approved drawing
- Documents
- MTC, dimensions and heat/lot traceability
Product Detail
Product Introduction
Welded titanium fittings are produced from welded tube, pipe, plate or fabricated segments and contain one or more controlled fusion welds. The weld route can enable larger sizes and special geometry, but requires explicit control of filler or autogenous procedure, shielding, heat tint, joint efficiency, NDE, heat treatment and documentation.
Product Specifications
| Product | Welded Titanium Fittings | Material Options | Titanium Grade 2, Grade 7 or Grade 12 as specified |
|---|---|---|---|
| Forms | Elbow, tee, reducer, cap, stub end or drawing-specific fitting | Typical Inquiry Range | NPS 1/2 to 24 typical standard inquiry range; large/custom sizes by review |
| Product Standard | ASTM B363 / ASME SB363 where applicable | Dimensional Basis | ASME B16.9, ASME B16.11 or approved drawing as applicable |
| Wall | Schedule or nominal wall thickness matched to the connected pipe and design | Ends | Butt-weld, socket-weld, threaded or drawing-defined ends |
| Manufacturing | Seamless, welded, formed, forged, machined or fabricated as specified | Surface | Pickled, cleaned, machined or project-specific finish |
| Inspection | Visual, dimensions, wall, ends and specified NDT | Documents | MTC, heat/lot traceability and inspection report |
Typical ranges are quotation guidance, not a stock guarantee. Final availability and tolerances are confirmed against the complete RFQ and design code.
Selection and Configuration
- Weld location and route: Identify longitudinal, circumferential or fabricated seams and the source-product specification.
- Welding controls: State qualified procedure, filler classification when used, shielding, cleaning, interpass limits and acceptance of heat tint.
- NDE and pressure design: Define visual, PT, RT or UT scope, acceptance criteria, joint efficiency and any pressure or leak test.
Send the piping specification or drawing
Include grade, NPS or OD, wall/schedule, geometry, ends, quantity, tests and documents.
Chemical Composition
Weight percent; maximum unless a range is shown. Titanium is the balance. The ordered grade controls.
| Grade / UNS | Pd | Mo / Ni | Fe | O | C | N | H | Ti |
|---|---|---|---|---|---|---|---|---|
| Grade 2 / R50400 | — | — | 0.30 | 0.25 | 0.08 | 0.03 | 0.015 | Balance |
| Grade 7 / R52400 | 0.12–0.25 Pd | — | 0.30 | 0.25 | 0.08 | 0.03 | 0.015 | Balance |
| Grade 12 / R53400 | — | 0.20–0.40 Mo; 0.60–0.90 Ni | 0.30 | 0.25 | 0.08 | 0.03 | 0.015 | Balance |
Mechanical Properties – Annealed Source Material Reference
| Grade | Ultimate Tensile Strength min | 0.2% Yield Strength min | Elongation min |
|---|---|---|---|
| Grade 2 | 345 MPa (50 ksi) | 275 MPa (40 ksi) | 20% |
| Grade 7 | 345 MPa (50 ksi) | 275 MPa (40 ksi) | 20% |
| Grade 12 | 483 MPa (70 ksi) | 345 MPa (50 ksi) | 18% |
Representative wrought-source material minima. Fitting acceptance, heat treatment and test specimens must follow the ordered material/product specification and size.
Typical Physical Properties
| Grade | Density | Elastic Modulus | Thermal Conductivity | Thermal Expansion |
|---|---|---|---|---|
| Grade 2 | 4.51 g/cm³ | Approx. 105 GPa | Approx. 16.4 W/m·K | Approx. 8.6 µm/m·K |
| Grade 7 | Approx. 4.51 g/cm³ | Approx. 105 GPa | Approx. 16 W/m·K | Approx. 8.6 µm/m·K |
| Grade 12 | Approx. 4.54 g/cm³ | Approx. 103 GPa | Approx. 16 W/m·K | Approx. 8.6 µm/m·K |
Typical engineering references, not inspection acceptance limits.
Certificates & Inspection Records

Services We Can Provide
Product Packaging
Fittings are capped or wrapped to protect clean ends, bevels, threads and machined faces. Items are separated by grade, size and heat/lot, then packed in reinforced cartons or export cases according to geometry and quantity.
Application Scenarios

Chemical Processing
Corrosion-resistant piping for acids, chlorides and process media after grade compatibility review.

Power & Energy
Cooling-water, condenser and auxiliary piping requiring traceable titanium components.

Marine & Desalination
Seawater and chloride-bearing piping systems designed for the selected titanium grade.
FAQ
When are welded titanium fittings considered?
They are commonly reviewed for larger sizes, special walls or fabricated geometry where seamless forming is impractical or unavailable.
Which weld information belongs in the RFQ?
State weld route, procedure qualification, filler, shielding, NDE method and coverage, acceptance criteria and required records.
Can welded replace seamless?
Only with design and purchaser approval after reviewing code, joint efficiency, corrosion service, NDE and documentation.
Leave Your Message
Related Technical Guides
Titanium Pipe Fitting Grade Comparison
Compare grades, construction, fabrication and service data.
Read technical guideTitanium Butt Weld Fittings Purchasing Matrix
Compare geometry, size, wall, ends, route and inspection.
Read technical guideTitanium Fittings for Seawater Piping
Coordinate material, piping design, fabrication and inspection.
Read technical guideTitanium RFQ Checklist
Prepare complete purchasing data and documents.
Read technical guide