An eddy current report should connect the delivered tube lot to a defined examination setup, reference response, examined extent and disposition. A statement that material was tested does not explain the acceptance basis or establish leak tightness.
Start with the inspection purpose
Separate new-tube manufacturing acceptance from an in-service bundle survey. Their identification systems, access conditions and decision criteria can differ. Record the governing purchase specification, approved procedure and applicable edition before interpreting results.
Follow the evidence chain
| Review point | Evidence to request | Question it resolves |
|---|---|---|
| Tube identity | Heat or lot, grade, dimensions and manufacturing route | Does this report apply to the delivered material? |
| Reference setup | Reference identification, relevant geometry and documented settings | What response was the examination compared against? |
| Coverage | Quantity and extent examined, inaccessible areas and limitations | What was actually inspected? |
| Results | Traceable indications and the stated evaluation basis | How was each relevant result classified? |
| Disposition | Acceptance, segregation, retest or other approved action | Which pieces are released? |
A reference response is not a universal flaw guarantee
Confirm that the reference and examination procedure are appropriate to the tube being supplied. Do not turn a response threshold into a guaranteed detectable flaw size without a qualified basis. A different material, geometry or examination arrangement needs its own assessment.
An in-service sample report can illustrate useful organization, but its damage categories, percentage-wall estimates and repair recommendations must not be copied into a new titanium-tube acceptance specification.
Close unexplained results before release
If identification, coverage or disposition is missing, request a corrected report or a documented clarification tied to the same lot. Keep retest results and their reason connected to the original record. A pass statement alone should not close an unresolved identification discrepancy.
Eddy current examination and leak testing answer different questions. Confirm separately which pressure or leak examination the governing order requires; do not describe one as automatically replacing the other.
For the product scope, review the B338, B861 and B862 comparison before defining the examination documents.